Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study
2016
Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …
Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial
2016
The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with …